Industrial Training Kits
We cater our clients with latest and standardized Industrial Training Kits. The whole range is well designed and arranged with supreme quality materials. Every product is manufactured with industrial laid parameters to offer accurate testing and understanding of engineering fundamentals and principles. Quality products at great prices available.
Fluidized Bed Dryer
Model ELE0001
"We are leading manufacturer and exporter of a wide range of Fluidized Bed Dryer. The Salt is fluidized, each particle meets the hot air, discharges moisture, gets dry and at the same time travels forward without any mechanical push. We have proven-technology for designing dryers of any capacity. In this state, the solids behave like a free flowing boiling liquid. Clients can avail this products as per there requirements. Scope of Experimentations: To study fluidization characteristics To study relationship between velocity of fluid and pressure drop per unit length Utilities Required: Electricity : 500 watts, 220 V, 1 Phase Floor Area : 0.75 m x 0.75 m Technical Details: Column : Material Borosilicate Glass Packing : Glass Beads Water tank : Material Stainless Steel, Capacity 30 Ltrs Water Circulation : FHP Pump, Crompton/Sharp make Flow Measurement : Rotameter for water Pr. Drop Measurement : Manometer The whole set-up is well designed and arranged in a good quality painted structure" View Details
"We are leading manufacturer and exporter of a wide range of Fluidized Bed Dryer. The Salt is fluidized, each particle meets the hot air, discharges moisture, gets dry and at the same time travels forward without any mechanical push. We have proven-technology for designing dryers of any capacity. In this state, the solids behave like a free flowing boiling liquid. Clients can avail this products as per there requirements. Scope of Experimentations: To study fluidization characteristics To study relationship between velocity of fluid and pressure drop per unit length Utilities Required: Electricity : 500 watts, 220 V, 1 Phase Floor Area : 0.75 m x 0.75 m Technical Details: Column : Material Borosilicate Glass Packing : Glass Beads Water tank : Material Stainless Steel, Capacity 30 Ltrs Water Circulation : FHP Pump, Crompton/Sharp make Flow Measurement : Rotameter for water Pr. Drop Measurement : Manometer The whole set-up is well designed and arranged in a good quality painted structure" View Details
Solid Liquid Extraction Bed Type
Model ELE0002
"With firm commitment to quality, we are engaged in offering excellent quality, Solid Liquid Extraction (Packed Bed Type) . These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. Post production, these products are stringently tested on varied grounds, to ensure their compliance with international quality standards. Features: Durability High tensile strength Resistance to corrosion" View Details
"With firm commitment to quality, we are engaged in offering excellent quality, Solid Liquid Extraction (Packed Bed Type) . These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. Post production, these products are stringently tested on varied grounds, to ensure their compliance with international quality standards. Features: Durability High tensile strength Resistance to corrosion" View Details
Mass Transfer Lab Equipment
Model ELE0003
"We are instrumental in offering superior quality Mass Transfer Lab Equipment to the esteemed customers, as per their specific demands. These mass transfer labs are designed in such a manner that our clients' exact requirements get fulfilled by us. In addition to this, we have gained expertise in offering customized products to the clients. Application Area Of Product: Solid-Liquid Extraction (Packed Bed Type) Absorption in Wetted Wall Column Packed Distillation Column Bubble Cap Distillation Column SIMPLE STEAM Distillation Set-up Swenson Walker Crystallizer Absorption in Packed Bed Liquid Liquid Extraction in Packed Bed Sieve Plate Distillation Column Spray Extraction Column Absorption in Sieve Plate Column Fluidized Bed Dryer Vapor in Air Diffusion Apparatus Forced Draft Tray Dryer Fixed Bed Absorption with Regeneration Solid in Air Diffusion Apparatus Natural Draft Tray Dryer York Scheibel Extraction Column Liquid in Liquid Diffusion Apparatus Rotary Dryer Batch Crystallizer Mass Transfer with/without Chemical Reaction (Solid-Liquid System) Solid-Liquid Extraction (Bonnoto type) Vapor-Liquid Equilibrium Set-Up Wetted Wall Column, Humidification & De-Humidification Study Experimental Water Cooling Tower Ion Exchange" View Details
"We are instrumental in offering superior quality Mass Transfer Lab Equipment to the esteemed customers, as per their specific demands. These mass transfer labs are designed in such a manner that our clients' exact requirements get fulfilled by us. In addition to this, we have gained expertise in offering customized products to the clients. Application Area Of Product: Solid-Liquid Extraction (Packed Bed Type) Absorption in Wetted Wall Column Packed Distillation Column Bubble Cap Distillation Column SIMPLE STEAM Distillation Set-up Swenson Walker Crystallizer Absorption in Packed Bed Liquid Liquid Extraction in Packed Bed Sieve Plate Distillation Column Spray Extraction Column Absorption in Sieve Plate Column Fluidized Bed Dryer Vapor in Air Diffusion Apparatus Forced Draft Tray Dryer Fixed Bed Absorption with Regeneration Solid in Air Diffusion Apparatus Natural Draft Tray Dryer York Scheibel Extraction Column Liquid in Liquid Diffusion Apparatus Rotary Dryer Batch Crystallizer Mass Transfer with/without Chemical Reaction (Solid-Liquid System) Solid-Liquid Extraction (Bonnoto type) Vapor-Liquid Equilibrium Set-Up Wetted Wall Column, Humidification & De-Humidification Study Experimental Water Cooling Tower Ion Exchange" View Details
Adsorption in Packed Bed
Model ELE0004
"We are offering superior quality Adsorption in Packed Bed to the esteemed customers, as per their specific demands. These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. We make sure to timely deliver the ordered products at the customers' end, via our wide distribution network. Utilities Required: Water Supply & Drain Electricity Supply: I Phase, 220VAC, 1.5kW Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted Specifications: Product Adsorption Setup Reactor Column Material Borosil Glass, different diameter with different height of packing (3 Nos.) Feed Tank Material Stainless Steel, Capacity 20 Ltrs., feed lines, drain valve etc. (1Nos.) Receiving Tank Material Stainless Steel, Capacity 20 Ltrs (1Nos.) Feed Circulation By pump, Magnetic drive made of Polypropylene (1Nos.) Flow Measurement Rota-meter 1 Nos. (for feed) Feed Piping PVC / SS size Stop Watch Electronic Control Panel On off switch, Mains Indicator etc. The setup is painted with good quality paints & mounted on a strong support." View Details
"We are offering superior quality Adsorption in Packed Bed to the esteemed customers, as per their specific demands. These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. We make sure to timely deliver the ordered products at the customers' end, via our wide distribution network. Utilities Required: Water Supply & Drain Electricity Supply: I Phase, 220VAC, 1.5kW Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted Specifications: Product Adsorption Setup Reactor Column Material Borosil Glass, different diameter with different height of packing (3 Nos.) Feed Tank Material Stainless Steel, Capacity 20 Ltrs., feed lines, drain valve etc. (1Nos.) Receiving Tank Material Stainless Steel, Capacity 20 Ltrs (1Nos.) Feed Circulation By pump, Magnetic drive made of Polypropylene (1Nos.) Flow Measurement Rota-meter 1 Nos. (for feed) Feed Piping PVC / SS size Stop Watch Electronic Control Panel On off switch, Mains Indicator etc. The setup is painted with good quality paints & mounted on a strong support." View Details
Bubble Cap Distillation Column
Model ELE0005
"The setup is designed to demonstrate principles of distillation in a Bubble Cap column. The column is made of Stainless Steel with seven plates for mounting the bubble caps. Each plate is provided with one bubble cap. An electrically heated re-boiler is installed at the bottom of the column. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary Experiments To study the Bubble Cap Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
"The setup is designed to demonstrate principles of distillation in a Bubble Cap column. The column is made of Stainless Steel with seven plates for mounting the bubble caps. Each plate is provided with one bubble cap. An electrically heated re-boiler is installed at the bottom of the column. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary Experiments To study the Bubble Cap Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
Natural Draft Tray Dryer
Model ELE0006
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under natural draft action created by hot air stream. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air works as the drying agent by natural action removes the moisture from the tray by passing towards the top openings. A digital temperature controller is used to control and measure the temperature of air stream l Experiments Determination of rate of drying of wet sawdust under different conditions of temperature Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater Material Saw dust @ 1Kg. Support table Size: 500Wx500Dx750H in mm" View Details
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under natural draft action created by hot air stream. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air works as the drying agent by natural action removes the moisture from the tray by passing towards the top openings. A digital temperature controller is used to control and measure the temperature of air stream l Experiments Determination of rate of drying of wet sawdust under different conditions of temperature Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater Material Saw dust @ 1Kg. Support table Size: 500Wx500Dx750H in mm" View Details
Forced Draft Tray Dryer
Model ELE0007
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from one side of the chamber and leave the chamber from other side removes the moisture from the tray. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream. >Experiments Determination of rate of drying of wet sawdust under different conditions of temperature and air flow Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater Material Saw dust @ 1Kg. Anemometer Air flow measurement" View Details
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from one side of the chamber and leave the chamber from other side removes the moisture from the tray. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream. >Experiments Determination of rate of drying of wet sawdust under different conditions of temperature and air flow Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater Material Saw dust @ 1Kg. Anemometer Air flow measurement" View Details
Fluidized Bed Dryer
Model ELE0008
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream and fluidization property of solid to dry. The set-up consists of a specially designed, vertical Column. The lower conical portion of the column is filled with moist solids. The material is supported on the screen mesh held between two flanges. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from lower side of the column and leave the column from top outlet removes the moisture of solids. At the top outlet of column a cyclone is provided to collect the solid particles taken out by the air stream. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream Experiments To study the fluidized bed drying Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater MaterialSaw dust @ 1Kg. Granular and free flowing solid of size I - 2 mm Anemometer Air flow measurement" View Details
"The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream and fluidization property of solid to dry. The set-up consists of a specially designed, vertical Column. The lower conical portion of the column is filled with moist solids. The material is supported on the screen mesh held between two flanges. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from lower side of the column and leave the column from top outlet removes the moisture of solids. At the top outlet of column a cyclone is provided to collect the solid particles taken out by the air stream. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream Experiments To study the fluidized bed drying Features Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater MaterialSaw dust @ 1Kg. Granular and free flowing solid of size I - 2 mm Anemometer Air flow measurement" View Details
Liquid Liquid Extraction In Packed Bed
Model ELE0009
"The setup is designed to demonstrate principles of liquid-liquid extraction and mass transfer operation in a packed column. The set up consists of a glass column, packing, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
"The setup is designed to demonstrate principles of liquid-liquid extraction and mass transfer operation in a packed column. The set up consists of a glass column, packing, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
York Scheibels Extraction Column
Model ELE0010
"The setup is designed to demonstrate principles of extraction and mass transfer operation in a YORK SCHEIBEL'S column. The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement. The glass column is divided into multiple stages; each stage consists of a woven wire mesh (calming) section and a mechanical agitation section. The agitator speed can be varied by drive. The presence of alternatively agitating and calming sections yield higher extraction efficiency than conventional packed column Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
"The setup is designed to demonstrate principles of extraction and mass transfer operation in a YORK SCHEIBEL'S column. The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement. The glass column is divided into multiple stages; each stage consists of a woven wire mesh (calming) section and a mechanical agitation section. The agitator speed can be varied by drive. The presence of alternatively agitating and calming sections yield higher extraction efficiency than conventional packed column Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
Spray Tower
Model ELE0011
"The setup is designed to demonstrate principles of spray extraction and mass transfer operation in a column. The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving trays and piping. Rotameter are provided for flow measurement Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
"The setup is designed to demonstrate principles of spray extraction and mass transfer operation in a column. The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving trays and piping. Rotameter are provided for flow measurement Experiments Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient Features Stainless Steel tanks and wetted parts Special arrangement for changing height of interface zone Continuous operation Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor Chemicals for trial as per your choice Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar. Water Supply & Drain as required" View Details
Solid Liquid Extraction Bonnoto Type
Model ELE0012
"The setup is designed to demonstrate principles of extraction in a Bonnotto type extraction column. It consists of a SS column, feed tank with heating arrangement, receiving tanks and piping. Rotameter is provided for flow measurement. The column is divided into multiple stages; each stage consists of a plate and a mechanical agitation section. The circular plates are arranged one above the other in opposite radial opening, yield higher extraction efficiency than conventional packed column. The solids are introduced at the top through a hopper spread over the top plate and pushed to slot to fall to the next plate below and so on to the bottom of the column. The solvent is introduced near the bottom of the column and it flow upward counter-currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. At the bottom of column a screw conveyor arrangement is done to remove the extracted solids driven by means of an electric motor. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed Experiments To determine the efficiency of a continuous counter-current Solid-Liquid Extraction Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply 1Phase, 220 V AC, 3 kW Chemicals for trial Solvent: 50ltrs Solid: 30kg as per your choice of system adopted as per your choice Water Supply & Drain as required" View Details
"The setup is designed to demonstrate principles of extraction in a Bonnotto type extraction column. It consists of a SS column, feed tank with heating arrangement, receiving tanks and piping. Rotameter is provided for flow measurement. The column is divided into multiple stages; each stage consists of a plate and a mechanical agitation section. The circular plates are arranged one above the other in opposite radial opening, yield higher extraction efficiency than conventional packed column. The solids are introduced at the top through a hopper spread over the top plate and pushed to slot to fall to the next plate below and so on to the bottom of the column. The solvent is introduced near the bottom of the column and it flow upward counter-currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. At the bottom of column a screw conveyor arrangement is done to remove the extracted solids driven by means of an electric motor. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed Experiments To determine the efficiency of a continuous counter-current Solid-Liquid Extraction Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Electric supply 1Phase, 220 V AC, 3 kW Chemicals for trial Solvent: 50ltrs Solid: 30kg as per your choice of system adopted as per your choice Water Supply & Drain as required" View Details
Sieve Plate Distillation Column
Model ELE0013
"The setup is designed to demonstrate principles of distillation in a Sieve Plate Column. The column is made of Stainless Steel material with seven sieve trays. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp. Measurement wherever is necessary Experiments To study the Sieve Plate Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
"The setup is designed to demonstrate principles of distillation in a Sieve Plate Column. The column is made of Stainless Steel material with seven sieve trays. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp. Measurement wherever is necessary Experiments To study the Sieve Plate Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
Packed Distillation Column
Model ELE0014
"The setup is designed to demonstrate principles of distillation in a Packed Column. The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water and it is supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary Experiments To study the Packed Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
"The setup is designed to demonstrate principles of distillation in a Packed Column. The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water and it is supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary Experiments To study the Packed Distillation Column Features Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Compact & stand alone set up Utilities Required Water Supply 2 LPM at 5 m head Drain Electricity Supply: 1Phase, 220 V AC, 6.5 kW Required Chemicals Refractrometer for analysis" View Details
MOTORISED GYROSCOPE
Model ELE0015
The set up consists of heavy stainless steel disc mounted on a horizontal shaft, rotated by a variable speed motor. The rotor shaft is coupled to a motor mounted on a trunion frame having bearings in a yoke frame, which is free to rotate about vertical axis. A weight pan on other side of disc balances the weight of motor. Rotor disc can be move about three axis. Torque can be applied by calculating the weight and distance of weight from the center of rotor. The gyroscopic couple can be determined. View Details
The set up consists of heavy stainless steel disc mounted on a horizontal shaft, rotated by a variable speed motor. The rotor shaft is coupled to a motor mounted on a trunion frame having bearings in a yoke frame, which is free to rotate about vertical axis. A weight pan on other side of disc balances the weight of motor. Rotor disc can be move about three axis. Torque can be applied by calculating the weight and distance of weight from the center of rotor. The gyroscopic couple can be determined. View Details