Other Engineering Lab Trainers
Manufacturers & Bulk Exporters of Scientific & Laboratory Equipment Suppliers for Schools, Colleges, Research Laboratories. Physics Lab, Chemistry Lab Supplies Lab.
Flamephoto Meters
Model HV-EXP2521
imple & Easy to Operate Narrow Band Interference Filters Dual Channel Display Na & K at Single Aspiration Flame Photometer Unit No. of Filters Na & K (Ca & Li optional) Na & K (Ca & Li optional) Range Na: 0-100 ppm Ca: 20-100 ppm K : 0-100 ppm Li: 10-100 ppm Na: 0-200 meq/l Ca: 0-2 meq/l K : 0-100 meq/l Li: 0-10 meq/l Sensitvity Na: 5 ppm Ca: 10 ppm K : 5 ppm Li: 10 ppm Na: 5 pmm Ca: 10 ppm K : 5 pmm Li: 10 ppm Display 2 1/2 digit bright LED Display Dual 2 1/2 digit bright LED Display Accuracy + 2% upto 40 ppm + 5% above 40 ppm + 2% upto 100 meq/l + 5% above 100 meq/l Repeatability + 2 Count + 2 Count Detector Silicon Photodiode Silicon Photodiode Filters Narrow band interference glass filters Narrow band interference glass filters Nebulizer Black bakelite, axial flow type Black bakelite, axial flow type Flame System LPG and dry oil free air LPG and dry oil free air Warmup time 10 minutes 10 minutes Power 230V + 10% AC 50 Hz 230V + 10% AC 50 Hz Size (LxBxH) 355 x 250 x 210 mm 455 x 250 x 210 mm Weight 6.5 kg (Approx.) 7.5 kg (Approx.) Compressor Unit Air Supply By Oil free mini compressor unit with pressure regular Combustion LPG controlled by precision regulator Power 230V +10% AC 50 Hz Size (LxBxH) 275 x 192 x 240 mm Weight 9 Kg (Approx.) Accessories Instrument with Na & K Filters, Instruction Manual, Dustcover, Chimney, Air Tubing. View Details
imple & Easy to Operate Narrow Band Interference Filters Dual Channel Display Na & K at Single Aspiration Flame Photometer Unit No. of Filters Na & K (Ca & Li optional) Na & K (Ca & Li optional) Range Na: 0-100 ppm Ca: 20-100 ppm K : 0-100 ppm Li: 10-100 ppm Na: 0-200 meq/l Ca: 0-2 meq/l K : 0-100 meq/l Li: 0-10 meq/l Sensitvity Na: 5 ppm Ca: 10 ppm K : 5 ppm Li: 10 ppm Na: 5 pmm Ca: 10 ppm K : 5 pmm Li: 10 ppm Display 2 1/2 digit bright LED Display Dual 2 1/2 digit bright LED Display Accuracy + 2% upto 40 ppm + 5% above 40 ppm + 2% upto 100 meq/l + 5% above 100 meq/l Repeatability + 2 Count + 2 Count Detector Silicon Photodiode Silicon Photodiode Filters Narrow band interference glass filters Narrow band interference glass filters Nebulizer Black bakelite, axial flow type Black bakelite, axial flow type Flame System LPG and dry oil free air LPG and dry oil free air Warmup time 10 minutes 10 minutes Power 230V + 10% AC 50 Hz 230V + 10% AC 50 Hz Size (LxBxH) 355 x 250 x 210 mm 455 x 250 x 210 mm Weight 6.5 kg (Approx.) 7.5 kg (Approx.) Compressor Unit Air Supply By Oil free mini compressor unit with pressure regular Combustion LPG controlled by precision regulator Power 230V +10% AC 50 Hz Size (LxBxH) 275 x 192 x 240 mm Weight 9 Kg (Approx.) Accessories Instrument with Na & K Filters, Instruction Manual, Dustcover, Chimney, Air Tubing. View Details
E/m By Short Solenoid Method (Magnatron Method)
Model HV-EXP2517
Objective:- To study charge of an elctron using Thomson Method. Features:- High Voltage Power Supply with one Meter Provided to measure the Deflection Voltage.Complete with intensity,Focus & Deflection controls. It is provided with accessories such as compass box,set of ELICO magnets,Teak wood stand with CRT mounted,Teak wood U stand with scale on both theorems for placing magnets. View Details
Objective:- To study charge of an elctron using Thomson Method. Features:- High Voltage Power Supply with one Meter Provided to measure the Deflection Voltage.Complete with intensity,Focus & Deflection controls. It is provided with accessories such as compass box,set of ELICO magnets,Teak wood stand with CRT mounted,Teak wood U stand with scale on both theorems for placing magnets. View Details
Electrical Resistance Tester
Model HV-EXP2394
Electrical Resistance Tester& The electric resistance of helmets is measured by applying a high voltage between an electrode placed in salt solution kept inside the helmet and another electrode placed in a salt solution bath in which the helmet is placed in inverted position. The voltage is slowly increased to the specified value and the current passing between the two electrodes measured for evaluating the electrical resistance of the helmet under test. The Electric Resistance Tester for helmets consists of a plastic container with an acrylic frame placed in its center for keeping the helmet under test on. The two electrodes are held in suitable clamps, one located inside the helmet and the other in the bath. A high voltage source is provided with the equipment for supplying the test voltage. It consists of a variac, a step-up transformer, a digital voltmeter, and a digital mili-ammeter with a pre-settable tripping currents. & All the parts used in the tester are made from materials that do not get affected by salt solution used for conducting the test. civil lab equipments manufacturers. Electrical Resistance Tester Lab equipment manufacturers,exporters and Electrical Resistance Tester Lab suppliers View Details
Electrical Resistance Tester& The electric resistance of helmets is measured by applying a high voltage between an electrode placed in salt solution kept inside the helmet and another electrode placed in a salt solution bath in which the helmet is placed in inverted position. The voltage is slowly increased to the specified value and the current passing between the two electrodes measured for evaluating the electrical resistance of the helmet under test. The Electric Resistance Tester for helmets consists of a plastic container with an acrylic frame placed in its center for keeping the helmet under test on. The two electrodes are held in suitable clamps, one located inside the helmet and the other in the bath. A high voltage source is provided with the equipment for supplying the test voltage. It consists of a variac, a step-up transformer, a digital voltmeter, and a digital mili-ammeter with a pre-settable tripping currents. & All the parts used in the tester are made from materials that do not get affected by salt solution used for conducting the test. civil lab equipments manufacturers. Electrical Resistance Tester Lab equipment manufacturers,exporters and Electrical Resistance Tester Lab suppliers View Details
3 Phase Induction Motor
Model HV-EXP2379
This is an AC 3 induction motor. This operates on 415V AC. This squirrel cage induction motor coupled to a 2KW shunt generator. ; Specifications: Volts: 415V - 3¢ Power: 2.2KW Current : 4.8A RPM: 1440 Frame: PM100.. View Details
This is an AC 3 induction motor. This operates on 415V AC. This squirrel cage induction motor coupled to a 2KW shunt generator. ; Specifications: Volts: 415V - 3¢ Power: 2.2KW Current : 4.8A RPM: 1440 Frame: PM100.. View Details
Water & Soil Analysis Kit
Model HV-EXP2523
3 1/2 digit LCD Display Mains cum Battery operated Measures pH, mV, Conductivity TDS, DO, Temperature & Turbidity Housed in VIP Briefcase pH Range 0 to 14pH 0 to 14pH 0 to 14pH Temp. Comp. 0oC (Manual) 0oC (Manual) 0oC (Manual) Resolution 0.01pH 0.01pH 0.01pH Accuracy +0.01 pH +0.01 pH +0.01 pH O.R.P./mV Range N.A. 0 to + 1999 mV 0 to + 1999 mV Resolution 0.01pH N.A. 1 mV Accuracy N.A. + 1 mV + 1 digit + 1 mV + 1 digit Conductivity Range 1 5 5 Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj Resolution 0.1 Micro mhos 0.1 Micro mhos 0.1 Micro mhos Accuracy + 0.5% FS + 0.5% FS + 0.5% FS Temperature Range 0o - 100oC 0o - 100oC 0o - 100oC Resolution 0.1oC 0.1oC 0.1oC Accuracy +0.1oC + digit +0.1oC + digit +0.1oC + digit T.D.S. Range 1 5 5 Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj Resolution 0.1ppm 0.1ppm 0.1ppm Accuracy +5% FSD +5% FSD +5% FSD D.O. Range 0-20 ppm 0-20 ppm N.A. Temp. Comp. 0.1 ppm 0.1 ppm N.A. Resolution +0.3 ppm +0.3 ppm N.A. Accuracy 5o to 50o (Manual) 5o to 50o (Manual) N.A. Turbidity Range 0-1000 NTU/JTU N.A. N.A. Resolution 1 NTU/JTU N.A. N.A. Display Selenium Photocell 3 1/2 digit LCD display Power Suppy 6.8v, 300mA 1.5V x 6 Dry Cells or 230V + 10% 50 Hz Accessories 230v + 10% and In-built Battery pH Combination Electrode, Conductivity / TDS Cell, DO Probe, Temp Probe, Standard Solution, D.O. Memberanes, Cell Container & Instruction Manual. View Details
3 1/2 digit LCD Display Mains cum Battery operated Measures pH, mV, Conductivity TDS, DO, Temperature & Turbidity Housed in VIP Briefcase pH Range 0 to 14pH 0 to 14pH 0 to 14pH Temp. Comp. 0oC (Manual) 0oC (Manual) 0oC (Manual) Resolution 0.01pH 0.01pH 0.01pH Accuracy +0.01 pH +0.01 pH +0.01 pH O.R.P./mV Range N.A. 0 to + 1999 mV 0 to + 1999 mV Resolution 0.01pH N.A. 1 mV Accuracy N.A. + 1 mV + 1 digit + 1 mV + 1 digit Conductivity Range 1 5 5 Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj Resolution 0.1 Micro mhos 0.1 Micro mhos 0.1 Micro mhos Accuracy + 0.5% FS + 0.5% FS + 0.5% FS Temperature Range 0o - 100oC 0o - 100oC 0o - 100oC Resolution 0.1oC 0.1oC 0.1oC Accuracy +0.1oC + digit +0.1oC + digit +0.1oC + digit T.D.S. Range 1 5 5 Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj Resolution 0.1ppm 0.1ppm 0.1ppm Accuracy +5% FSD +5% FSD +5% FSD D.O. Range 0-20 ppm 0-20 ppm N.A. Temp. Comp. 0.1 ppm 0.1 ppm N.A. Resolution +0.3 ppm +0.3 ppm N.A. Accuracy 5o to 50o (Manual) 5o to 50o (Manual) N.A. Turbidity Range 0-1000 NTU/JTU N.A. N.A. Resolution 1 NTU/JTU N.A. N.A. Display Selenium Photocell 3 1/2 digit LCD display Power Suppy 6.8v, 300mA 1.5V x 6 Dry Cells or 230V + 10% 50 Hz Accessories 230v + 10% and In-built Battery pH Combination Electrode, Conductivity / TDS Cell, DO Probe, Temp Probe, Standard Solution, D.O. Memberanes, Cell Container & Instruction Manual. View Details
Desauty Bridge
Model HV-EXP2519
It is a simple form of bridge giving maximum accuracy while comparing capacitance in term of resistance. Three decade dials x10, x100 and 1000 ohms from one arm. The other arm has also decade dials x10, x100 and 1000 ohms. A special morse key is fitted in the centre of the two arms connecting the battery and the galvanometer. The connection are engraved on the panel which is fitted to a teak wood polished case. All the coils are calibrated on Imported Testing Bridge. Accuracy ± 0.5 to 1%. De- sauty Bridge's It is a simple form of bridge giving maximum accuracy while comparing capacitance in term of resistance. Three decade dials x10, x100 and 1000 ohms from one arm. The other arm has also decade dials x10, x100 and 1000 ohms. A special Morse key is fitted in the centre of the two arms connecting the battery and the galvanometer. The connection is engraved on the panel which is fitted to a teak wood polished case. All the coils are calibrated on Imported Testing Bridge. Accuracy ± 0.5 to 1%. View Details
It is a simple form of bridge giving maximum accuracy while comparing capacitance in term of resistance. Three decade dials x10, x100 and 1000 ohms from one arm. The other arm has also decade dials x10, x100 and 1000 ohms. A special morse key is fitted in the centre of the two arms connecting the battery and the galvanometer. The connection are engraved on the panel which is fitted to a teak wood polished case. All the coils are calibrated on Imported Testing Bridge. Accuracy ± 0.5 to 1%. De- sauty Bridge's It is a simple form of bridge giving maximum accuracy while comparing capacitance in term of resistance. Three decade dials x10, x100 and 1000 ohms from one arm. The other arm has also decade dials x10, x100 and 1000 ohms. A special Morse key is fitted in the centre of the two arms connecting the battery and the galvanometer. The connection is engraved on the panel which is fitted to a teak wood polished case. All the coils are calibrated on Imported Testing Bridge. Accuracy ± 0.5 to 1%. View Details
Energy Band Gap For Semi Conductor Diode
Model HV-EXP2503
Objective: to plot reverse saturation current vs temperature in reverse bioased pn junction diode. Features: instrument comprises of DC regulated power supply 0-20CDC/150ma two round meters for voltage & current measurement, one PN junction diode (GE type) is kept in oven, connections of supplies, meters & diode brought out at 4mm sockets. Also provided with oven wih temperature control knob.. View Details
Objective: to plot reverse saturation current vs temperature in reverse bioased pn junction diode. Features: instrument comprises of DC regulated power supply 0-20CDC/150ma two round meters for voltage & current measurement, one PN junction diode (GE type) is kept in oven, connections of supplies, meters & diode brought out at 4mm sockets. Also provided with oven wih temperature control knob.. View Details
Smart Card Trainer Board
Model HV-EXP2495
FEATURES ·; Contactless transmission of data and supply energy (no battery needed). ·; Operating distance : Up to 100mm (depending on antenna geometry). ·; Operating frequency : 13.56 MHz ·; Fast data transfer : 106 kbit/s ·; High data integrity : 16 Bit CRC, parity, bit coding, bit counting. ·; True anticollision ·; Typical ticketing transaction: <100 ms (including backup management). EEPROM ·; 1 Kbyte, organized in 16 sectors with 4 blocks of 16 bytes each (one block consists of 16 byte). ·; User definable access conditions for each memory block. ·; Data retention of 10 years ·; Write endurance 100.000 cycles SECURITY ·; Mutual three pass authentication (ISO/IEC DIS9798-2). ·; Data encryption on RF-channel with replay attach protection. ·; Individual set of two keys per sector (per application) to support multi-application with key hierarchy. ·; Unique serial number for each device. ·; Transport key protects access to EEPROM on chip delivery. ·; Read Block ·; Write Block ·; Document : Decrements the contents of block and stores the result in temporary internal data register. ·; Increment : Increments the contents of block and stores the result in data register. ·; Restore : Move the contents of block into the data register. ·; Transfer : Writes the contents of the temporary internal data register to a value block. INTERFACING MODULES ·; Electric Lock door with Software in VB and training. ·; Attendance System etc.. View Details
FEATURES ·; Contactless transmission of data and supply energy (no battery needed). ·; Operating distance : Up to 100mm (depending on antenna geometry). ·; Operating frequency : 13.56 MHz ·; Fast data transfer : 106 kbit/s ·; High data integrity : 16 Bit CRC, parity, bit coding, bit counting. ·; True anticollision ·; Typical ticketing transaction: <100 ms (including backup management). EEPROM ·; 1 Kbyte, organized in 16 sectors with 4 blocks of 16 bytes each (one block consists of 16 byte). ·; User definable access conditions for each memory block. ·; Data retention of 10 years ·; Write endurance 100.000 cycles SECURITY ·; Mutual three pass authentication (ISO/IEC DIS9798-2). ·; Data encryption on RF-channel with replay attach protection. ·; Individual set of two keys per sector (per application) to support multi-application with key hierarchy. ·; Unique serial number for each device. ·; Transport key protects access to EEPROM on chip delivery. ·; Read Block ·; Write Block ·; Document : Decrements the contents of block and stores the result in temporary internal data register. ·; Increment : Increments the contents of block and stores the result in data register. ·; Restore : Move the contents of block into the data register. ·; Transfer : Writes the contents of the temporary internal data register to a value block. INTERFACING MODULES ·; Electric Lock door with Software in VB and training. ·; Attendance System etc.. View Details
Electrical Machine Trainers
Model HV-EXP2393
Electrical Machine Trainers Backed by rich industrial experience, we have been able to come up with supreme quality Electrical Machine Trainers. These products are widely known in the market for its durability and compact design. Developed with latest technology and finest raw-material, these products are in compliance with the defined parameters of the industry. Apart from this, we strive to provide complete assurance over the offered product. Features: High efficiency Corrosion-resistance Low maintenance Highly durable Easy-installation . View Details
Electrical Machine Trainers Backed by rich industrial experience, we have been able to come up with supreme quality Electrical Machine Trainers. These products are widely known in the market for its durability and compact design. Developed with latest technology and finest raw-material, these products are in compliance with the defined parameters of the industry. Apart from this, we strive to provide complete assurance over the offered product. Features: High efficiency Corrosion-resistance Low maintenance Highly durable Easy-installation . View Details
Squirrel Cage Induction Motor
Model HV-EXP2391
Squirrel Cage Induction Motor 1. Outer yoke made up of High grade cast iron frame. 2. High grade silicon stamping Stator with hydraulically pressed. 3. Dynamically balance dies casted Rotor of High grade Aluminum used. 4. Larger size of bearings for longer life and trouble free operations. 5. Vacuum pressure impregnation for stator - ensuring high insulation strength. 6. All the terminals on terminals Box are properly engraved. 7. Brake drum pulley are Dynamically Balanced. 8. Sturdy base frame with heavy duty bolt with CP handle and also highly accurate dial type ;spring balance to give proper readings of the machines. 9. Ratings: For 3ph, 415Volts, 50Hz. ;0.5H.P to 15HP.10. ;Ratings: for 1ph 220V, 50Hz. ; ; ; ; ; ; ; ; ; capacitor Start / Run Motor 0.5H.P to 2 HP.. View Details
Squirrel Cage Induction Motor 1. Outer yoke made up of High grade cast iron frame. 2. High grade silicon stamping Stator with hydraulically pressed. 3. Dynamically balance dies casted Rotor of High grade Aluminum used. 4. Larger size of bearings for longer life and trouble free operations. 5. Vacuum pressure impregnation for stator - ensuring high insulation strength. 6. All the terminals on terminals Box are properly engraved. 7. Brake drum pulley are Dynamically Balanced. 8. Sturdy base frame with heavy duty bolt with CP handle and also highly accurate dial type ;spring balance to give proper readings of the machines. 9. Ratings: For 3ph, 415Volts, 50Hz. ;0.5H.P to 15HP.10. ;Ratings: for 1ph 220V, 50Hz. ; ; ; ; ; ; ; ; ; capacitor Start / Run Motor 0.5H.P to 2 HP.. View Details
Single Phase Transformer
Model HV-EXP2389
Single phase double wound copper transformer having primary 230VAC and secondary 115V AC with a rated capacity of 1KVA. The primary and secondary terminals are brought out for conducting laboratory experiment with legend printed for convenience. This is assembled in a powder coated MS metal box. ; Specifications: Primary : 230 V AC Secondary with tappings at 86.6% and at 50% of primary voltage. Rated capacity: 1KVA Terminations: Separate 4mm Banana terminals at input and outputs Enclosure: Powder coated MS metal cabinet, with separate screw terminal for earth connection.. View Details
Single phase double wound copper transformer having primary 230VAC and secondary 115V AC with a rated capacity of 1KVA. The primary and secondary terminals are brought out for conducting laboratory experiment with legend printed for convenience. This is assembled in a powder coated MS metal box. ; Specifications: Primary : 230 V AC Secondary with tappings at 86.6% and at 50% of primary voltage. Rated capacity: 1KVA Terminations: Separate 4mm Banana terminals at input and outputs Enclosure: Powder coated MS metal cabinet, with separate screw terminal for earth connection.. View Details
DC Shunt Generator No Load Tests On DC Shunt Generator
Model HV-EXP2383
Open Circuit Test Objective:;To obtain the magnetization characteristic and therefore determine the critical field resistance and critical speed of the given dc shunt generator. Preview: The EMF induced in a DC machine is proportional to the flux per pole, the number of conductors and speed. This EMF depends on speed and flux. As the flux increases the EMF increases beyond a point the flux gets saturated. The BH curve of the core depicts the magnetization curve of the machine. (A) Critical Speed of a DC Shunt Generator Objective:;To determine the critical speed of a dc shunt generator. With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite. Preview: With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite. ; Equipment Required:;All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format) 1. 2HP Shunt machines mechanically coupled both are identical 220V 2HP 1500rpm. 2. 3-4 point DC Starter for the above 3. Suitable Loading rheostat 4. Digital tachometer 5. Suitable Double tube rheostat 6. Suitable Single tube rheostat 7. Suitable Digital Voltmeter DC 8. Suitable Digital Voltmeter DC 9. Suitable Digital Ammeter DC 10. Rectifier Unit 0-240V DC @ 1.5KVA with power failure protection.. View Details
Open Circuit Test Objective:;To obtain the magnetization characteristic and therefore determine the critical field resistance and critical speed of the given dc shunt generator. Preview: The EMF induced in a DC machine is proportional to the flux per pole, the number of conductors and speed. This EMF depends on speed and flux. As the flux increases the EMF increases beyond a point the flux gets saturated. The BH curve of the core depicts the magnetization curve of the machine. (A) Critical Speed of a DC Shunt Generator Objective:;To determine the critical speed of a dc shunt generator. With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite. Preview: With the fixed excitation and variable speed, as the speed reduces the OCC proportionally slides down so that the no load voltage reduces. At a particular speed, called the critical speed, the OCC is tangential to the Rf line and as a result the generator fails to excite. ; Equipment Required:;All the measuring instruments associated with each experiment are industrial grade. These instruments are housed in an elegant cabinet as a package. Range of instruments and accessories (standard format) 1. 2HP Shunt machines mechanically coupled both are identical 220V 2HP 1500rpm. 2. 3-4 point DC Starter for the above 3. Suitable Loading rheostat 4. Digital tachometer 5. Suitable Double tube rheostat 6. Suitable Single tube rheostat 7. Suitable Digital Voltmeter DC 8. Suitable Digital Voltmeter DC 9. Suitable Digital Ammeter DC 10. Rectifier Unit 0-240V DC @ 1.5KVA with power failure protection.. View Details
Digital Turbidity Meters
Model HV-EXP2522
Range 0 to 200 JTU 0 to 1000 JTU 2 Ranges 0 to 20.00 NTU 0 to 200.00 NTU 2 Ranges Resolution 1 JTU 0.1, 1 NTU Accuracy +3% FS + 1 digit +2% FS + 1 digit Sample System 30 mm clear glass tube 30 mm clear glass tube Light Source 6.8 V, Tungsten Lamp 6.8 V, Tungsten Lamp Detector Photo diode Photo diode Display 3 1/2 digit LED display 3 1/2 digit LED display Power 220V+ 10% AC 50 Hz 220V+ 10% AC 50 Hz Size (LxBxH) 305 x 305 x 165 mm 305 x 305 x 165 mm Weight 4 kg (approx.) 4 kg (approx.) Accessories Test Tube Set, Operation Manual & Dustcover Other Models Analog Nephelometer Battery cum Mains Operated also Available. View Details
Range 0 to 200 JTU 0 to 1000 JTU 2 Ranges 0 to 20.00 NTU 0 to 200.00 NTU 2 Ranges Resolution 1 JTU 0.1, 1 NTU Accuracy +3% FS + 1 digit +2% FS + 1 digit Sample System 30 mm clear glass tube 30 mm clear glass tube Light Source 6.8 V, Tungsten Lamp 6.8 V, Tungsten Lamp Detector Photo diode Photo diode Display 3 1/2 digit LED display 3 1/2 digit LED display Power 220V+ 10% AC 50 Hz 220V+ 10% AC 50 Hz Size (LxBxH) 305 x 305 x 165 mm 305 x 305 x 165 mm Weight 4 kg (approx.) 4 kg (approx.) Accessories Test Tube Set, Operation Manual & Dustcover Other Models Analog Nephelometer Battery cum Mains Operated also Available. View Details
Digtal TDS Meters
Model HV-EXP2520
Highly Stable and Accurate Cell Constant Adjustment Facility Available in Lab & Field models Temperature Coefficient Correction facility Display 3 1/2 Digit LED 3 1/2 Digit LED Range 5 Ranges 0-1000 ppt Mohs/cm 2 Ranges 0-2000 ppm 0-20 ppt Temperature Compensation Manual 0-50oC - Cell Constrant Adjustment Adjustable Pre Adjustable Conductivity Cell Platinum DIP Platinum DIP Measuring Frequency 1000 Hz 1000 Hz Accuracy +1% FSI +1% FSI Power 230v + 10% 1 x 9V Battery Dimensions 76 x 275 x 175 mm 85 x 28 x 165 mm Weight 2 kg. (Approx.) 0.8 kg. (Approx.) Accessories TDS Cell,Operation Manual, Dust Cover. View Details
Highly Stable and Accurate Cell Constant Adjustment Facility Available in Lab & Field models Temperature Coefficient Correction facility Display 3 1/2 Digit LED 3 1/2 Digit LED Range 5 Ranges 0-1000 ppt Mohs/cm 2 Ranges 0-2000 ppm 0-20 ppt Temperature Compensation Manual 0-50oC - Cell Constrant Adjustment Adjustable Pre Adjustable Conductivity Cell Platinum DIP Platinum DIP Measuring Frequency 1000 Hz 1000 Hz Accuracy +1% FSI +1% FSI Power 230v + 10% 1 x 9V Battery Dimensions 76 x 275 x 175 mm 85 x 28 x 165 mm Weight 2 kg. (Approx.) 0.8 kg. (Approx.) Accessories TDS Cell,Operation Manual, Dust Cover. View Details
Sodium Vapour Lamp Transformer
Model HV-EXP2518
Sodium Vapour lamp Transformer are housed in iron cabinet and nicely painted. A) 35 Watt B) 55 Watt. View Details